Application |
Models |
Main
Features |
Heating, air
ventilation, conditioning |
TBL100 |
bimetal thermometer
for controlling ventilation shafts, ranges 0...80șC and -20...60șC,
class 1, IP 50 |
|
TBX |
bimetal thermometer
with conic bulb, class 1, ranges -20...40șC upto 0...250șC, IP 50
(IP65 = TBW) |
|
TBH |
bimetal thermometer
with different short bulb lengths, class 1, ranges -20...60 șC up
to 0...250șC, IP 50 |
|
TBHA (TB-Fix) |
bimetal thermometer
for measurements of liquids in insulated pipes without contacting
the medium, class 1, ranges -20...40șC up to 0...160șC, IP 50 |
|
TBA 72 |
pipe mounting
bimetal thermometer for measurements directly on the pipe, accuracy
± 1%, ranges -20...40șC, 0...60șC and 0...120șC |
Industry, plant
engineering |
TB 32 |
bimetal thermometer
for fix mounted machine parts, accuracy ± 1%, ranges 0...120șC up
to 0...250șC, IP 50 |
|
TB 40, 63 |
bimetal thermometer,
complete stainless steel, accuracy ± 1%, ranges -30...30șC up to 100...500șC,
IP 52 |
|
TB |
standard bimetal
thermometer in a wide range of applications and specifications, class
1, ranges -30...30șC up to 100...500șC |
|
TOS / TOF |
organic liquid
filled spring thermometer with fixed bulb or capillary tube in a wide
range of specifications, accuracy ± 1%, ranges -60...40șC up to 0...250șC,
IP 50 |
Industry, chemistry,
food, pharma |
TBD |
bimetal thermometer,
complete stainless steel in different specifications and for various
applications, class 1, ranges -70...50șC up to 0...600șC, IP 67 |
|
TSS / TSF |
Gas filled
thermometer with fixed bulb or capillary tube, in a wide range of
specifications, class 1, ranges -200...50șC up to 0...800șC, IP 67 |
Climate &
Humidity
Application |
Models |
Main
Features |
Heating, ventilation,
air conditioning |
KAF 100 |
For humidity
measurmets of air and noncorrosive gases in drying rooms, ventilation
shafts, etc., range 0...100% relative humidity, accuracy ± 4% |
Humidity measuring |
KAF 564 |
Accurate determination of
humidity from dry and humid temperatures, accuracy ± 1% of relative
humidity, ranges -10...30șC, 0...50șC, 0...100șC |
Climate measuring recorder |
KRK 501 |
Temperature and humidity
recorder with mechanical or quartz clockwork, ranges -35...45șC upto
-10...50șC (several ranges in șF are available), accuracy: temperature
± 1%, humidity ± 4% |
Climate measuring |
|
Several room thermometer
and thermo-hygrometer |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Whenever
you see me you will find a PDF file. Click here to download