Series 672 Digitally
Compensated Pressure Transmitter |
Series 672 Pressure
Transmitters provide accuracy only in more expensive units by
employing advanced digital compensation. Built-in signal conditioner
compensates for both linearity and thermal error thus providing a
4-20mA loop output with an accuracy of ±0.1%. The piezoresistive
sensor is housed in a rugged, all welded NEMA 4X (IP56) 316L stainless
steel enclosure Models available measureing in psi with a 1/4"
NPTM process connection and a 3 ft (1m) vented cable or measuring in
bar with a 1/4" BSP(M) process connection and a vented connector.
|
PHYSICAL
DATA GENERAL Service: Liquids or gases compatible with 316L stainless steel. Output: 4 to 20 mA, 2 wire. Supply Voltage: 10 to 32 VDC. Loop Resistence: 1000 Ohms @ 32 VDC. Accuracy: ±0.1% F.S. (includes non-linearity, hysteresis, and repeatability). Zero Offset: ±0.25% F.R.O. Stability: Less than 0.5% FS/year. Maximum Overload Pressure: 300% upper range limit. Temperature Limits: Compensated: -13 to 185°F (-25 to 85°C), Operating: -40 to 212°F (-40 to 100°C) Storage: -58 to 212°F (-50 to 100°C). Wetted Parts: 316L Stainless Steel. Enclosure: NEMA 4X (IP56). Electrical Connections: 3 ft. (1 m) integral cable with strippd ends and vented for 672-41XX models or hermetically sealed connector for 672-42XX models. Weight: 6.4 oz (180 g) for 672-41XX models or 5.9 oz (165 g) for 672-42XX.
|
STOCKED MODELS
|